High-frequency 8MHz EIS Potentiostat galvanosatt model CS360

Brand Name : CorrTest

Model Number : CS360

Certification : ISO CE

Place of Origin : China

MOQ : 1 set

Payment Terms : T/T

Supply Ability : 1000 per year

Delivery Time : 20 working days

Packaging Details : standard CARTON

Contact Now

Single-channel potentiostat/galvanostat with EIS Model CS360 consists of a DDS arbitrary function generator, a potentiostat /galvanostat and an FRA. With the help of built-in dual 24-bit Delta-sigma AD converters, it achieves excellent stability and high potential (1mV) and current(1pA) resolutions.With EIS frequency up to be 8MHz, CS360 has been an ideal tool for the study of solid-state electrolyte.

Applications of CS360 potentiostat

- Energy materials (Solid-state battery, Li-ion battery, solar cell, fuel cell, supercapacitors, etc)

- Electrocatalysis (HER, OER, ORR, CO2RR, NRR, water splitting)

- Reactive mechanisms of electrosynthesis, electrodeposition (electroplating), anodic oxidation, electrolysis

- Metallic corrosion; corrosion inhibitor, coating and cathodic protection efficiency

High-frequency 8MHz EIS Potentiostat galvanosatt model CS360

With virtues of high energy density, fast charging &discharging, and long lifespan, solid-state batteries are widely used in electric vehicles, wearable devices and so on. Featured by leak-proofness, flame retardancy and inhibition of dendrite growth, solid-state electrolytes enhance the safety of batteries. ElS is an important technique to study the performance of solid-state batteries. It can provide information about charge transfer, electrochemical reactions, etc by measuring EIS in various frequency regions, further providing important theoretical basis and technical support for the development of high-performance fully solid-state batteries.

The EIS frequency can be up to 8MHz for CS360 potentiostat/galvanostat/electrochemical workstation, which can meet the need of high-frequency EIS test on solid electrolytes. Study of solid electrolytes especially focus on impedance behavior in high-frequency region. It helps us to quantify the electronic &ionic conductivity, find microstructural problems of the material (such as grain boundary effects), and thus provide guidance on material optimization, and battery performance improvement.

High-frequency 8MHz EIS Potentiostat galvanosatt model CS360

Solid-state battery holder

High-frequency 8MHz EIS Potentiostat galvanosatt model CS360

Waveform of the EIS test

Specifications - CS360 potentiostat

Support 2-, 3- or 4-electrode configuration

Maximum applied Potential: ±10V

Maximum output current: ±2A

Potential control accuracy: 0.1%×full range±1mV

Current control accuracy: 0.1%×full range

Potential resolution: 1μV

Current sensitivity:1pA

Potential rise time: ≤1μs

Reference electrode input impedance:1013Ω||5pF

Input basis current: ≤10pA

Potential range: ±200mV, ±2.5V, ±5V, ±10V, 4 ranges

Current range: ±200pA ~ ±2 A, 11 ranges

Compliance voltage: ±30V

CV and LSV scan rate: 0.001mV/s~10kV/s

CA and CC pulse width: 0.0001~65,000s

Current increment during scan: 1mA@1A/ms

Potential increment during scan: 0.02mV @1V/ms

SWV frequency: 0.001~100kHz

DPV and NPV pulse width: 0.001~100s

AD data acquisition: 16bit@1MHz, 20bit @1kHz

DA Resolution: 20 bit

Minimum Potential increment in CV: 0.02mV

Low-pass filters: covering 7-decade

Potential and current range: Manual/Auto switch

Ground mode: Floating, Earthing, supports ZRA

Communication: USB2.0, RJ45 Ethernet

Operating System: Windows 10/11

Power supply: 90~240V AC 50/60Hz

Weight / Dimensions : 6.5kg, 36 x 30 x16 cm

EIS (Electrochemical Impedance Spectroscopy)

Signal generator

Frequency range:10μHz~8 MHz

AC amplitude: 1mV~2500mV

DC Bias: -10~+10V

DDS output impedance: 50Ω

Frequency accuracy: 0.1%

Signal resolution: 0.1mV RMS

Waveform: sine wave, triangular wave and square wave

Wave distortion: <1%

Scanning mode: logarithmic/linear, increase/decrease

Signal analyzer

Integral time: minimum:10ms or the longest time of a cycle

Maximum:106 cycles or 105 s

Measurement delay: 0~105s

DC offset compensation

Potential automatic compensation range: -10V~+10V

Current compensation range: -2A~+2A

Bandwidth: 8-decade frequency range, automatic and manual setting

Techniques

Stable polarization:

Open Circuit Potential (OCP)

Potentiostatic (I-T curve)

Galvanostatic

Potentiodynamic (Tafel plot)

Galvanodynamic (DGP)

Transient Polarization:

Multi Potential Steps

Multi Current Steps

Potential Stair-Step (VSTEP)

Galvanic Stair-Step (ISTEP)

Chrono Method:

Chronopotentiometry (CP)

Chronoamperametry (CA)

Chronocaulometry (CC)

Voltammetry:

Linear Sweep Voltammetry (LSV)

Cylic Voltammetry (CV)

Staircase Voltammetry (SCV)

Square Wave Voltammetry (SWV)

Differential Pulse Voltammetry (DPV)

Normal Pulse Voltammetry (NPV)

Differential Normal Pulse Voltammetry (DNPV)

AC Voltammetry (ACV)

2nd harmonic AC Voltammetry (SHACV)

Fourier Transform AC Voltammetry (FTACV)

Electrochemical Impedance Spectroscopy:

Potentiostatic EIS (Nyquist, Bode)

Galvanostatic EIS

Potentiostatic EIS (Optional freq.)

Galvanostatic EIS(Optional freq.)

Mott-Schottky

Potentiostatic EIS vs. Time (Single freq.)

Galvanostatic EIS vs. Time (Single freq.)

Corrosion Measurements:

Cyclic polarization curve (CPP)

Linear polarization curve (LPR)

Electrochemical Potentiokinetic Reactivation (EPR)

Electrochemical Noise (ECN)

Zero resistance Ammeter (ZRA)

Battery testing:

Battery Charge and Discharge

Galvanostatic Charge and Discharge (GCD)

Potentiostatic Charging and Discharging (PCD)

Potentiostatic Intermittent Titration Technique (PITT)

Galvanostatic Intermittent Titration Technique (GITT)

Amperometric:

Differential Pulse Amperometry (DPA)

Double Differential Pulse Amperometry (DDPA)

Triple Pulse Amperometry (TPA)

Integrated Pulse Amperometric Detection (IPAD)

Stripping Voltammetry:

Potentiostatic Stripping,

Linear Stripping,Staircase Stripping

Square Wave Stripping

Differential Pulse Voltammetry Stripping

Normal Pulse Voltammetry Stripping

Differential Normal Pulse Voltammetry Stripping

Extensions:

Electrochemical Stripping/ Deposition

Bulk Eletrolysis with Coulometry (BE)

Rs Measurement